3-6
Chapter 3
Installing the System
Installing in a Rack
SMG-3200 system can be installed in a rack or on a table. Installation of SMG-3200 in a rack
enables more convenient usage and management. This section provides procedures for SMG-3200
system installation in a rack. For the case of SMG-3200 system installation on a table, skip this
section and refer to the following ‘
Connecting Ground Cable
’ section.
Safety Precautions
To ensure general safety, always follow these precautions before stalling the SMG-3200 on a rack.
y
Elevated Operating Ambient Temperature-
The details should be provided so that
consideration shall be give to installing the equipment in an environment compatible with the
manufacturer’s maximum rated ambient temperature (45
°
C).
y
Reduced Air Flow-
Installation of the equipment in a rack shall be such that the amount of air
flow required for safe operation of the equipment is not compromised.
y
Mechanical Loading-
Mounting of the equipment in the rack shall be such that a hazardous
condition is not achieved due to uneven mechanical loading.
y
Circuit Overloading-
Consideration should be given to connection of the equipment to the
supply circuit and the effect that overloading circuits may have on overcurrent protection and
supply wiring. Appropriate consideration of the equipment nameplate rating should be used
when addressing this concern.
y
Reliable Earthing-
Reliable earthing of the rack mounting equipment should be maintained.