9.
It is very important that the PCR cleaner be cleaned. Vacuum or blow off any residual toner from the
foam/felt.
10.
With the PCR Cleaner Assy. removed the drum can easily be removed by lifting it out. See Figure 14
11.
Clean out any remaining toner from the cartridge.
12.
Remove all the Gears from the right side. See Figure 15
13.
Press in on the top tab of the roller plate to release it. See Figure 16
14.
Press in on the bottom tab of the roller plate to release it. See Figure 17
FIGURE 12
FIGURE 13
FIGURE 14
FIGURE 15
Page 5 of 11
Summit Laser Products - Samsung SF-5100 Toner Cartridges
4/21/2008
http://www.summitechnologies.com/docs/0307/0307.asp