POSITION : Defines the position and detection direction of a line or fenced area.
1) LINE FENCE
- SEL POS : Selects a position from POS1,POS2.
- X POS / Y POS : Adjust the size and position of the selected line fence.
- DIRECTION
·
·
·
-
2) AREA FENCE
- SEL POS :
Selects a position from POS1 ~ POS4.
- X POS / Y POS : Adjust the size and position of the selected area fence.
- DIRECTION
·
·
·
DIR2 : Detects objects moving left to right on the fence line.
DIR1/2 : Detects all objects moving crosswise on the fence line.
RETURN : Select this to save the POSITION menu settings and return to the
TRACKING menu.
IN : Detects objects entering the fenced area.
OUT : Detects objects exiting the fenced area
IN/OUT : Detects all objects entering and exiting the fenced area.
- RETURN : Select this to save the POSITION menu settings and return to the
TRACKING menu.
▶
RETURN : Select this to save the TRACKING menu settings and return to the
INTELLIGENCE menu.
•
inteLLiGence
:
INTELLIGENCE
1. DETECTION
2. TRACKING
OFF
3. FIXED/MOVED
OFF
4. TAMPERING
5. DETECT BOX
6. ALARM OUT
7. SETUP CONFIG
8.
RETURN
►
Commands the camera to
motion-detect and trace an object.
OFF
OFF
OFF
OFF
-
-
DETECTION : Since the camera detects
motion without any additional external sensor,
you can monitor activity more effcient.
TRACKING
1. TYPE
2. COUNT
OFF
3. DISPLAY
ON
4. FILL
5. POSITION
6.
RETURN
►
OFF
LINE
▶
TRACKING : Commands the camera to detect
and trace a moving object.
TYPE : Two types, line and area, of fences
are available.
▶
COUNT : Displays the number of times
that an object enters or leaves a fenced area.
▶
DISPLAY : Determines whether to use the
fence selected in the FENCE.
▶
FILL : Fill or remove color from the FENCE.
DIR1 : Detects objects moving right to left on the fence line.
Содержание SCO-6081R