background image

10

 – DIGITAL COLOR CAMERA

Introduction

n

  Input/Output Connector

This connector has input and output ports for RS-485 control signals, DAY/NIGHT switching, and alarm 
output signals.

No.

Function

Description

1

ALARM OUT

Alarm out port for motion detection. (Open collector type)

2

GND

Grounding Port.

3

TRIGGER IN

Displays the current still image when it receives the Trigger signal.
(Normal Open Type)

4

SHUTTER (S0)

This is a port for selecting an external high speed shutter mode. 
If connected in LOW (0V), it will become ON inside.

5

SHUTTER (S1)

This is a port for selecting an external high speed shutter mode. 
If connected in LOW (0V), it will become ON inside.

6

SHUTTER (S2)

This is a port for selecting an external high speed shutter mode. 
If connected in LOW (0V), it will become ON inside.

7

5V OUT

Power supply port for RS-485 JIG. Use within typical DC +5V 100mA

8

DAY/NIGHT IN

This is a port for DAY&NIGHT conversion.
High(DC +3V~+5V) : DAY(COLOR) Mode, 
Low(0V) : NIGHT(BW) Mode

9

RS-485 DATA-

This is a port for connection to RS-485 DATA- signal line.

10

RS-485 DATA+

This is a port for connection to RS-485 DATA+ signal line.

o

  SETUP Switch

This switch is used to set the function or property. When this switch is pressed for at least 2 seconds, the 
MAIN MENU appears.

ef

 (Left/Right) :  

By pressing this switch left or right, you can move left or right on the menu or change the 
displayed value.

cd

 (Up/Down) :  

By pressing this switch up or down, you can move up or down on the menu.

‹

 :  

When you press this switch in the menu, the selected function is confi rmed. To enter a submenu, press 
this button.

p

  Power Display LED

When the power is normally connected, the red LED lights.

q

  Video OUT Port

This is connected to the Video Input Port of the monitor and it outputs the Video signals.

r

  GND

This is a grounding port.

s

  Power Connection Port

This is connected to the Power cable.

CO
CO

Conn
the A

P

N

1

2

3

4

No

Содержание SCC-B2335

Страница 1: ...MERA user manual SCC B2335 P SCC B2035P imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsungsecurity com...

Страница 2: ...ect multiple cameras to a single adapter Exceeding the capacity may cause abnormal heat generation or re Securely plug the power cord into the power receptacle Insecure connection may cause re When in...

Страница 3: ...e the already installed product be sure to turn off the power and then move or reinstall it Remove the power plug from the outlet when then there is a lightning Neglecting to do so may cause re or dam...

Страница 4: ...ided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles...

Страница 5: ...Iris Lens Connector 11 Mounting the lens 11 Connecting cables and checking operation 12 How to use OSD Menu Using Icons in the Menu 13 Main Menu 13 Pro le 14 Camera Setup 16 Intelligence 23 Privacy zo...

Страница 6: ...make the IR Cut ltering function inactive under the illumination below the normal value High Sensitivity It implements images of high sensitivity using the up to date SONY Super HAD Progressive CCD L...

Страница 7: ...English 7 ENG Introduction and h t ting ure e ra t PRODUCT ACCESSORIES Product Accessories Accessories Camera Camera Holder Mount Auto Iris Lens Connector User s Manual Main Product C Mount Adapter...

Страница 8: ...ble transmits the power and signals from the camera for controlling the Auto Iris Lens Mount Adapter Fixing Grooves These grooves are used when xing screws of the mount adapter connected to the bracke...

Страница 9: ...English 9 ENG Introduction alled ing Rear Panel n o r q p s AC24 DC12V SCC B2335 P n o q s AC220V 240V SCC B2035P p...

Страница 10: ...cal DC 5V 100mA 8 DAY NIGHT IN This is a port for DAY NIGHT conversion High DC 3V 5V DAY COLOR Mode Low 0V NIGHT BW Mode 9 RS 485 DATA This is a port for connection to RS 485 DATA signal line 10 RS 48...

Страница 11: ...Type 1 Damp Power 12V 2 Damp Not applicable 3 Drive Video Signal 4 Drive Ground Note You can switch a control type of the lens in the menu MOUNTING THE LENS When using the CS lens Mount the CS lens by...

Страница 12: ...pter to the camera using the Slot Head screwdriver as shown in the picture GND cable with the white stripe line 1 2 3 4 5 6 7 8 1 ALARAM OUT 2 GND 3 TRIGGER IN 4 SHUTTER SO 5 SHUTTER S1 6 SHUTTER S2 7...

Страница 13: ...select QUIT in the menu MAIN MENU MAIN MENU PROFILE CAMERA SET INTELLIGENCE PRIVACY ZONE OTHER SET COMMUNICATION SYSTEM INFO LANGUAGE PROFILE You can set a mode according to the camera installation co...

Страница 14: ...User setting allowed User setting allowed MID User setting allowed User setting allowed WDR LEVEL User setting allowed User setting allowed 0 User setting allowed User setting allowed WHITE BAL User s...

Страница 15: ...tting allowed 0 User setting allowed 0 User setting allowed BLUE User setting allowed 0 User setting allowed 0 User setting allowed DETAIL 2 2 2 2 2 ITS It will be set automatically so you can easily...

Страница 16: ...que name to a camera If you press the SETUP switch with the CAMERA ID menu selected you will see the appropriate screen You can enter up to 54 alphanumeric or special characters for the CAMERA ID Sele...

Страница 17: ...ill see a menu where you can set the WDR options You can adjust the shutter speed in WDR LEVEL and the brightness in WEIGHT You can also select any of OUTDOOR and INDOOR in WHITE BAL ALC LENS DC LEVEL...

Страница 18: ...ength of the AGC level for a control of the camera motion This is available only if the SENS UP menu is set to AUTO You can select one from S SLOW SLOW NORM FAST and F FAST for the AGC level If you mo...

Страница 19: ...UTO X6 AUTO X8 AUTO X12 AUTO X16 AUTO X24 AUTO X32 AUTO X48 AUTO X64 AUTO X96 AUTO X128 AUTO X256 AUTO X512 FIX X2 FIX X4 FIX X6 FIX X8 FIX X12 FIX X16 FIX X24 FIX X32 FIX X48 FIX X64 FIX X96 FIX X128...

Страница 20: ...S MID DWELL TIME 2S NIGHT DAY BRIGHTNESS MID DWELL TIME 5S MASK AREA 1 2 You can set the BURST option to OFF ON or select to output the Burst signal in NIGHT mode You can select from LOW MID and HIGH...

Страница 21: ...UE and BRIGHTNESS The screen will be displayed in colors according to your settings WHITE BAL DAY NIGHT NIGHT BRIGHTNESS MID MODE AWC RED 00 I BLUE 00 I R GAIN 0248 B GAIN 0247 Note You can set the va...

Страница 22: ...chronization If selecting LINE the camera will use the external power source frequency for the synchronization You can adjust the LL PHASE Note Use of DC 12V will x V SYNC to INT which can not be chan...

Страница 23: ...the system displays PASS if the object s center line passes through the line while it displays ENTER or EXIT if the center point passes through the area FENCE LINE OFF AREA OFF You can set the positi...

Страница 24: ...jects overlap with each other or one object separates in multiple directions FIXED MOVED If an object on the screen suddenly disappears or an object comes out of nowhere and stays for a certain time t...

Страница 25: ...at moves as you change the PIXEL LEVEL to set the position PRIVACY ZONE SET1 PIXEL LEVEL 4 POINT POSITION How to set the point You can set each position of the 4 points If you press the SETUP switch i...

Страница 26: ...RESS and LANGUAGE will not be restored to the default OSD COLOR BW R G B You can set the OSD On screen Display color to COLOR or B W COMMUNICATION eCOMMUNICATIONf RS 485 PROTOCOL SAMSUNG BAUD RATE 960...

Страница 27: ...ing the protocol address baud rate serial number camera version and EEP version LANGUAGE eLANGUAGEf ENGLISH FRAN AIS DEUTSCH ESPA OL ITALIANO The camera supports 5 different languages Select a preferr...

Страница 28: ...8 Lux 0 00008 Lux 512 times 1 2 30 IRE 0 00047 Lux 0 000047 Lux 512 times 1 2 15 IRE 0 00023 Lux 0 000023 Lux Functions Number of Privacy Zone 12 Polygonal Method Day Night DAY NIGHT AUTO EXT Motion D...

Страница 29: ...ol Coaxitron Data On Coax cable Yes with SCX RD100 RS 485 Yes Multi Protocol 8ea Environmental Conditions Operating Temperature 10 C 50 C Humidity Less than 90 Power Power Requirement AC24V 10 60Hz 0...

Страница 30: ...08 Lux 0 00008 Lux 512 times 1 2 30 IRE 0 00047 Lux 0 000047 Lux 512 times 1 2 15 IRE 0 00023 Lux 0 000023 Lux Functions Number of Privacy Zone 12 Polygonal Method Day Night DAY NIGHT AUTO EXT Motion...

Страница 31: ...erating Temperature 10 C 50 C Humidity Less than 90 Power Power Requirement SCC B2335P AC24V 10 50Hz 0 3Hz DC12V 10 SCC B2035P AC220V 10 50Hz 0 3Hz Power Consumption With DC Lens In Normal operation S...

Страница 32: ...the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resourc...