![Samsung S3F84B8 Скачать руководство пользователя страница 139](http://html.mh-extra.com/html/samsung/s3f84b8/s3f84b8_user-manual_347832139.webp)
S3F84B8_UM_REV 1.00
6 INSTRUCTION SET
6-17
6.3.5 BCP — BIT COMPARE
BCP
dst,src.b
Operation
:
dst(0) – src(b)
The specified bit of source is compared to (subtracted from) bit zero (LSB) of destination. Zero
flag is set if the bits are same; otherwise it is cleared. The contents of both operands remain
unaffected by the comparison.
Flags
:
C
: Unaffected.
Z
: Set if the two bits are the same; cleared otherwise.
S
: Cleared to “0”.
V
: Undefined.
D
: Unaffected.
H
: Unaffected.
Format
:
Bytes Cycles
Opcode
(Hex)
Addr Mode
dst src
opc
dst | b | 0
src
3
6
17
r0
Rb
NOTE:
In the second byte of instruction format, the destination address is four bits, the bit address ‘b’ is three bits,
and the LSB address value is one bit in length.
Example
:
Given R1 = 07H and register 01H = 01H:
BCP R1,01H.1
R1 = 07H, register 01H = 01H
If the destination working register R1 contains the value 07H (00000111B) and the source register
01H contains the value 01H (00000001B), the statement “BCP R1,01H.1” compares bit one of
the source register (01H) and bit zero of the destination register (R1). Since the bit values are not
identical, the zero flag bit (Z) is cleared in the FLAGS register (0D5H).