TROUBLESHOOTING
- The refrigerator of this model has BLDC FAN motor. BLDC motor is driven by DC 7~12V.
- On the normal condition of COMP ON, it operates together with F-FAN motor.
If door is opened and closed once at a high ambient temperature, it will be operated after 1 minute
delay.
Therefore, you are advised not to taken it for an error.
-. If there is a trouble, you should select the self-diagnostic function to check the trouble before power off.
4-2-2. If FAN does not operate
Start
Is COMP ON ?
Door & MICOM State
Door
F FAN pulse voltage
CN75#5(Black)
The voltage measured around 2~3V
with multi-meter though the voltage is
very weak because of pulse signal
Display for checking the self-diagnostic function
R FAN ERROR
typical PCB Ground
CN10#3(Black)
F
MICOM
(#50)
Close
Open
5V(High)
0V(Low)
0V(Low)
5V(High)
R MICOM(#3)
Right and Left
Execute manual
operation
FAN work normally
Repair the connection
of Door switch
Replace MAIN PCB
1) R-FAN
2) F-FAN
3) C-FAN
typical PCB Ground
CN1#3(Black)
Power ON with 5 minutes
delay after power OFF.
For preventing the over
load of compressor)
Expected causes
Check that if FAN-MOTOR has failure
itself.
Check that if wiring connection has bad
contact.
Check the input of the fan motor rotation
pulse when motor fan operates.
CN75-5(F),6(R),7(C)will generate the pulse signal when motor rotates.
These signals will be inputted into MICOM.
Unless signals are not inputted during motor operating, will be ON 10
seconds after fan Off. But if signals are not still entered, the above operation
will restart four times more.
If signals are not entered continuously, the motor will be restarted after 10
seconds.
This function is effective when the normal operation of motor would be
restrained by foreign matters such as ice.
Checking method of R,F,C FAN Motor voltage
The voltage between PCB typical Ground CN1-"3"(Black) and
R FAN ; CN75#2(Yellow) shall be less than DC 7~12V.
F FAN ; CN75#3(Orange) shall be less than DC 7~12V.
C FAN ; CN75#4(Sky-blue) shall be less than DC 7~12V.
- Recheck if resistance values are different after measuring.
Is the voltage between MAIN
PCB CN1#3 (Black) and CN75#2
(Yellow) around DC7~12V?
Is the voltage between MAIN
PCB CN1#3 (Black) and CN75#3
(Orange) around DC7~12V?
Is the voltage between MAIN
PCB CN1#3 (Black) and CN75#4(Sky
-blue) around DC7~12V?
Is the voltage between MAIN
PCB CN1#3 (Black) and CN30#2
(Purple) around 0V?
Is the voltage between MAIN
PCB CN1#3 (Black) and CN30#1
(Black) around 5V?
Does DC7~12V alternate with
below DC 2V between MAIN PCB
CN1#3(Black) and CN75-#2(Yellow)
Does DC7~12V alternate with below
DC 2V between MAIN PCB CN1#3(Black)
and CN75#3(Orange)
Does DC7~12V alternate with below
DC 2V between MAIN PCB CN1#3(Black)
and CN75#4(Sky-blue)
In initial power to appliance, the compressor
and fans of fresh food/ freezer, compressor
fan operate. If freezer temperature is
sensed of 41
by momentary power
failure, fans will operate after 5 minutes.
Reference
F FAN ERROR
C FAN ERROR
Содержание RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH RF266AASH
Страница 2: ......
Страница 19: ...18 Refrigerator PRODUCT SPECIFICATIONS 2 9 Cooling Air Circulation Freezer ...
Страница 85: ...84 EXPLODED VIEW PARTS LIST 5 4 Disassembly of Freeze Door 10 2 7 2 7 4 7 1 7 3 10 1 10 9 7 2 2 1 3 5 4 6 6 9 ...
Страница 104: ...103 EXPLODED VIEW PARTS LIST 5 4 Disassembly of Freeze Door 10 2 7 2 7 4 7 1 7 3 10 1 10 9 7 2 2 1 3 5 4 6 6 9 ...
Страница 109: ...108 EXPLODED VIEW PARTS LIST 5 6 Disassembly of Refrigerator Door Right 1 2 5 5 6 4 3 6 3 8 2 8 1 6 4 6 1 6 2 7 8 ...
Страница 120: ...119 8 1 Whole block diagram 8 Shematic Diagram AC115V AC115V AC115V 8 1 1 MODEL RF266 BETTER ...
Страница 121: ...120 Shematic Diagram AC115V AC115V AC115V 8 1 2 MODEL RF265 GOOD RF26NB ...
Страница 122: ...121 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 1 Sheet 1 of 2 ...
Страница 123: ...122 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 2 Sheet 2 of 2 ...