![Samsung RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH RF266AASH Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/samsung/rf265aars-rf266aars-rf26nbrs1rf265aabp-rf266aabp-rf26nbbp1rf265aawp-rf266aawp-rf26nbsh1rf265aash-rf266aash/rf265aars-rf266aars-rf26nbrs1rf265aabp-rf266aabp-rf26nbbp1rf265aawp-rf266aawp-rf26nbsh1rf265aash-rf266aash_service-manual_353420056.webp)
55
TROUBLESHOOTING
4) If Ambient Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN32 inserted
correctly?
Is Ambient Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN32#1(White)
to CN1#3(Black) normal?
Is the input voltage of
IC01 MICOM #59 normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
Ambient : CN32#1
#4 measuring resistance value
** Placed in the right top table of upper hinge.
** 0 : Short trouble /
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #59,
CN32#1(White) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of Ambient Sensor resistance
CN32#1(White)
#4(White)
- Compare the temperature table after the
measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
Ambient Connector CN32#1(White) to
CN1#3(Black) PCB typical Ground
Checking method of Ambient Sensor voltage
- Measure the voltage of Sensor Check Point #7(IC01 MICOM #59)
on PCB or CN32#1(White)
CN1#3(Black)
- Compare the temperature table after the measure
Measuring voltage of CN32#1(White)
CN1#3(Black) are below
typical PCB Ground
CN1#3(Black)
Start
YES
YES
YES
Содержание RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH RF266AASH
Страница 2: ......
Страница 19: ...18 Refrigerator PRODUCT SPECIFICATIONS 2 9 Cooling Air Circulation Freezer ...
Страница 85: ...84 EXPLODED VIEW PARTS LIST 5 4 Disassembly of Freeze Door 10 2 7 2 7 4 7 1 7 3 10 1 10 9 7 2 2 1 3 5 4 6 6 9 ...
Страница 104: ...103 EXPLODED VIEW PARTS LIST 5 4 Disassembly of Freeze Door 10 2 7 2 7 4 7 1 7 3 10 1 10 9 7 2 2 1 3 5 4 6 6 9 ...
Страница 109: ...108 EXPLODED VIEW PARTS LIST 5 6 Disassembly of Refrigerator Door Right 1 2 5 5 6 4 3 6 3 8 2 8 1 6 4 6 1 6 2 7 8 ...
Страница 120: ...119 8 1 Whole block diagram 8 Shematic Diagram AC115V AC115V AC115V 8 1 1 MODEL RF266 BETTER ...
Страница 121: ...120 Shematic Diagram AC115V AC115V AC115V 8 1 2 MODEL RF265 GOOD RF26NB ...
Страница 122: ...121 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 1 Sheet 1 of 2 ...
Страница 123: ...122 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 2 Sheet 2 of 2 ...