11
Product sPecifications
2-2) Specifications
Defrost Control From 12 to 30hrs(comp. run time)
Thermo Bimetal Protector 140°F(60°C)(off) 104°F(40°C)(on)
Defrost Thermistor(502AT) 50°F(10°C)(off)
Electrical Rating AC115V 60Hz 11.6 Amps
Maximum Current Leakage 0.25 mA
Maximum Ground Path Resistance 0.1 Ohm
Energy Consumption 481 kWh/year
Refrigerator,°F 44°F(7°C) ~ 34°F(1°C)
Freezer,°F 5°F(-15°C) ~ -8°F(-23°C)
Run Time,% < 40 < 80
Refrigerant Charge (R134a) 5.64 oz(160g)
Compressor(MKV190C-L2J) 1314 Btu/hr(0.385kw)
Compressor oil Freol 5
∝
15c
R Capillary tube(Dia, Length) 0.032
"
,118
"(0.82mm,3500mm)
Clearance must be provided for air circulation.
AT T O P 1
" ( 2 5 m m )
AT SIDES 1
"(25mm)
AT REAR 2
"(50mm)
Fan
Fan
Fan
Fan
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
Heat exchanger
Heat exchanger
Fan
Fan
(Air inlet)
(Air inlet)
Heat exchanger
ElECTRICAl SPECIFICATIONS
Freezer
Refrigerator
NO lOAD PERFORmANCE
REFRIGERATION SySTEm
INSTAllATION
Fan
Fan
Fan
Fan
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
Heat exchanger
Heat exchanger
Fan
Fan
(Air inlet)
(Air inlet)
Heat exchanger
Содержание RF263BEAE SERIES
Страница 13: ...12 product specifications 2 3 Interior Views ...
Страница 20: ...19 product specifications 2 7 1 Principle of freezeer ...
Страница 94: ...93 troubleshooting SPM FREEWHEELING DIODE VOLTAGE VALUE ...
Страница 103: ...102 schematic diagram 7 3 1 Main 7 3 CIRCUIT DIAGRAM This document can not be used without Samsung s authorization ...
Страница 104: ...103 schematic diagram 7 3 2 INVERTER This document can not be used without Samsung s authorization ...