CHECK THE INSTALLATION STATUS
This document cannot be used without Samsung's authorization.
③
If buzzer does not sound
Does it soundif
press a button on the inner panel
(fridge room)?
Is the connection
between inner panel PBA CN01 and
Cabi Wire Harness normal?
Is the connection
betweenBUZZER PBA CN1 and Assy Top
Table Wire Harness normal?
MAIN PCB normal,
BUZZER normal
Check Connector Contact Defect
Check Connector Contact Defect.
Recheck the button pressing
force and mechanical problem.
Yes
No
No
No
Yes
Yes
Start
Buzzer is installed on the Assy Top Table in this model.
When alarm sounds continuously without stop (related with buzzer sound)