* Self-diagnosis CHECK LIST
LED
Item
Diagnostic method
Location image
F
R
Freezer
Sensor
The voltage of MAIN PCB CN51-"9"
↔
"11" : shall be between 4.5V~1.0V
1
Fridge
Sensor
The voltage of MAIN PCB CN51-"14"
↔
"13" : shall be between 4.5V~1.0V
2
Freezer compartment
defrosting sensor
The voltage of MAIN PCB CN51-"5"
↔
"7"
: shall be between 4.5V~1.0V.
4
Fridge compartment
defrosting sensor
The voltage of MAIN PCB CN51-"12"
↔
"13" : shall be between 4.5V~1.0V.
5
External air
sensor
The voltage of MAIN PCB CN51-"4"
↔
"6"
: shall be between 4.5V~1.0V
6
Ice Maker (Freezer)
Sensor Error
(OPTION)
The voltage of MAIN PCB CN30-"9"
↔
"11" : shall be between 4.5V~1.0V
8
Humidity
sensor
The voltage of MAIN PCB CN51-"4"
↔
"8"
: shall be between 4.5V~1.0V
13