INSTALLATION
TECHNICAL MANUAL
PART 3 MAY 2010
3.6
The system database is
NOT
stored in SRAM. The system database is now stored in the on-
board NAND FLASH. This data can remain in NAND-FLASH until the system is defaulted.
TO DEFAULT THE SYSTEM, simply power ON the OS7400 while this switch (S1) is in
the OFF position. After defaulting the system, always power the OS7400 off and set
this switch S1 to the ON position, then boot the system back up again. System can
also be defaulted by selecting “MEMORY CLEAR” in MMC 811.
DIP SWITCH USE (S2)
ON
OFF
4 DIGIT STATION NUMBERS
SW8
3 DIGIT STATION NUMBERS
4 DIGIT STATION GROUPS
SW7
3 DIGIT STATION GROUPS
4 DIGIT TRUNK NUMBERS
SW6
3 DIGIT TRUNK NUMBERS
RESERVED
SW5
RESERVED
COUNTRY SELECT
SW4
COUNTRY SELECT
COUNTRY SELECT
SW3
COUNTRY SELECT
COUNTRY SELECT
SW2
COUNTRY SELECT
COUNTRY SELECT
SW1
COUNTRY SELECT
Switches 1 through 4 select the country the system is installed in.
4 3 2
1
Country
OFF OFF OFF
OFF
Korea
OFF OFF OFF
ON
USA
OFF OFF ON
OFF
UK
OFF OFF ON
ON
Italy
OFF ON OFF
OFF
Australia
OFF ON OFF
ON
New
Zealand
OFF ON ON
OFF
Holland
OFF ON ON
ON
Denmark
Switch 5 is reserved.
These DIP switches will not take effect unless the switches are set in the wanted position
and the system memory is cleared manually by using the Memory Backup switch. (This
means defaulting the system by booting the system with the S1 switch in the OFF
position.)