OfficeServ 7400
INSTALLATION
TECHNICAL MANUAL
PART 5 MAY 2010
5.8
INSTALLATION PROCEDURE
This section describes how to install OfficeServ 7150 PoE on the floor or inside a rack.
Select an Installation Method
OfficeServ 7150 may be installed either on the floor or inside a 19 inch rack.
1)
Ground the system to the grounding lug at the rear side of 7150.
2)
Remove the blanking plate from the slot where the PoE-M PSU module is to be inserted.
Do not remove a blanking plate from unused slots.
3)
Insert the PoE-M module into the slot.
4)
Connect an external battery with proper capacity if required.
5)
Connect AC input voltage.
INSTALLATION IN A RACK
Install in a standard 19”data rack.
If an enclosed rack is used, check if proper ventilation system has been installed in the
rack.
If an open rack is used, do not to block the front of the OfficeServ 7150 fan.
Tools Required
One medium size Phillips screw driver
One cross bar bracket and three screws
Two rack mount brackets and six screws
Two fixing screws