OfficeServ 7200-S
INSTALLATION
TECHNICAL MANUAL
PART 3 MAY 2010
3.26
Front panel components of the 8SLI/8SLI2:
Table 3.13 Ports and LEDs of the 8SLI/8SLI2
Ports & LEDs
Function Description
P1~P8
Station ports for analog phones.
P1~P8 LED
These LEDs indicate the operation status of the ports.
- Off: The station is not active on a call.
- On: The station is active on a call.
•
Port 1 (P1) supports Power Failure Transfer function
(Refer to Section 3.5).
•
See Section 7.1.2 for port Pinout/Wiring
.
•
Do not connect devices with a total REN greater than 5.0 to this card.
3.3.12 PLIM (PoE LAN INTERFACE MODULE)
The PLIM sends/receives data to/from the internal LAN, and provides 16 ports of 10/100 Base-
T Ethernet interfaces. It functions as a Layer 2 LAN switch. The PLIM supports Power over
Ethernet (IEEE 802.3af). This means that it can provide power to any IEEE 802.3af compliant
device that is connected to any of its Ethernet ports. All Samsung IP phones and SMT-R2000
Dual-Band APs can receive power when connected to PLIM. When connected to the PLIM
Ethernet port, these devices no longer need the AC power adapter.
The PLIM can be installed in slots 1 through 5 of any cabinet.
When a PLIM acts as an unmanaged switch, it simply performs as a simple data switch (10/100
Base-T).
PLEASE NOTE:
The PLIM/PLIM2 module uses the -48V rail from the OS7200-S power supply to provide power
to connected devices over Ethernet. The OS7200 power supply provides up to 2200mA of
output current
. PER EACH OS7200 CABINET (not per system),
the SUM of all current
drawn from 1) devices powered by PLIM cards, 2) digital key sets connected to DLI ports
3) analog devices connected to SLI ports.