OfficeServ 7200-S
INSTALLATION
TECHNICAL MANUAL
PART 10 MAY 2010
10.1
PART 10. ADDING CARDS TO THE SYSTEM
10.1 ADDING STATIONS AND TRUNKS
1)
Power the OfficeServ 7200-S OFF before adding a new board. Locate a compatible empty
card slot. Pull the ejector handle forward, then insert the new card into the slot and push
firmly in the middle of the card ejector to ensure that it is fully inserted into the back plane
connector.
2)
Restore power to the system.
3)
After the new cards are inserted, the system must be told to recognize the new cards. This
is done through the use of MMC 806 Card Pre-Install. Use this MMC for each new card that
is installed.
4)
The new cards must be assigned directory numbers according to the system numbering
plan in MMC 724. The technician must know the software port assignments of the new
cards so the ports can be assigned correct numbers.