3-2
Chapter 3
OfficeServ 100 Specifications
Environmental Limits
OPERATING TEMPERATURE
32–104 °F / 0–40 °C
STORAGE TEMPERATURE
13–158 °F / -10.5–70 °C
HUMIDITY
10%–90% non-condensing
Cable Requirements
EQUIPMENT
CABLE
AWG / mm
MAX METRES
DIGITAL KEYSET
1 PR.
TWISTED
#24 / 0.5
400
ADD-ON MODULE
1 PR.
TWISTED
#24 / 0.5
400
SINGLE LINE STATION
1 PR.
TWISTED
#24 / 0.5
1000
DOOR PHONE
2 PR.
TWISTED
#24 / 0.5
100*
WBS24
2 PR.
TWISTED
#24 / 0.5
400
*This is the maximum distance a door phone can be from the DPIM. The DPIM can be up to 274 cable
metres from the KSU.
Power Supply
RESERVE POWER DURATION ESTIMATES (IN MINUTES)*
UPS CAPACITY IN VOLT AMPS (VA)
NO. OF STATIONS
250
400
450
600
900
1250
2000
4
65 160 200 245 360 490 930
8
45 110 135 160 240 320 625
12
40 90 115 140 200 280 535
16
30 75 90 110 160 220 415
24
25 50 70 85 120
175
380
32
20 45 60 75 100
150
330
*These are approximate values (in minutes) based on an idle system. The greater the C.O. line activity
on the system, the lower these readings will become. In addition, specific UPS devices, due to their in-
ternal construction, can have greater or lesser values.
Содержание OFFICESERV 100 Series
Страница 1: ...OfficeServ 100 General Description Enterprise IP Solutions ...
Страница 11: ...OfficeServ100 1 3 Figure 1 1 OfficeServ 100 Basic Key Service Unit ...
Страница 78: ...4 42 Chapter 4 Business Features Package Sample SMDR Printout ...
Страница 90: ...Samsung Business Communications Brookside Business Park Greengate Middleton Manchester M24 1GS ...