38
_ installation instructions
To adjust flame low setting
Identify which burner is exhibiting too high or too low of simmer rate via manifold
panel graphics.
1.
Rotate a knob to "LO" position and remove the knob
from the valve stem while the flame is lit.
2.
Carefully push the screw driver into the stem of the
valve, until it reaches the bypass screw. Make sure the
screwdriver flathead is seated into the bypass screw
groove.
3.
Rotate valve bypass screw clockwise to decrease "LO" setting flame output,
or rotate bypass screw counter clockwise to increase "LO" setting flame
output.
To adjust the outer flame, turn the bypass valve
screw located at the valve stem. To adjust the
inner flame, remove the manifold panel, and then
turn the bypass valve screw located on the right
of the valve stem.
Bypass
screw
Dual valve
Inner flame
bypass screw
Outer flame
bypass screw