![Samsung NX583G0VBSR Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/samsung/nx583g0vbsr/nx583g0vbsr_service-manual_352796052.webp)
52
4. Troubleshooting
This document can not be used without Samsung’s authorization.
4-2 Cooktop Malfunction
The flame looks abnormal (Gas)
No
Ok
Ok
Ok
Ok
*Check whether the burner heads
and caps are properly assembled.
Yellow tip / Lift flame
*Place the burner heads and caps
properly.
END
No
*Check the orifice nozzle diameter.
[NG / LP]
*Replace the orifice nozzle.
END
No
*Check the direction of the
orifice at the GPR.
*Apply the right direction of the orifice.
END
No
*Check the air shutter opening
[Broil / Bake burner]
*Adjust the air shutter opening.
END
END
.2
0)
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner location
BTU Rate
Orifice Size [mm]
RF
1
17,000
1.92
RF
2
16,000
1.92
LF
12,000
1.60
RR
5,000
1.01
LR
9,500
1.40
CTR
1
9,500
1.38
CTR
2
9,500
1.40
BAKE
18,000
1.90
BROIL
1. MODEL NX58F5500SS / NX58F5500SB / NX58F5300SS
2. MODEL NX58F5300SS
13,500
1.64
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner location
BTU Rate
Orifice Size [mm]
RF
12,500
1.06
LF
10,000
0.98
RR
4,000
0.62
LR
7,500
0.83
CTR
1
7,500
0.83
CTR
2
7,500
0.83
BAKE
15,000
1.15
BROIL
11,500
1.02