Wiring diagram
Make sure of a earthing.
Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire.
If earthing is incomplete, electric shock or fire may occur.
DHW tank (Continued)
Turn on the DHW tank and hydro unit after completing electric wiring works.
Do not disassemble the wirings out of the unit while the unit is operating.
Circuit breaker shall be installed for safety and maintenance .
1
40.4
66T
DATE CODE
CAL LOT NO.
59T 4117
ø5.56
2 HOLES
59T
4
2
42.52
50.8
63.5
1
4
2
Outer casing
L
N
Electrical connections – Technical Data:
Electric element:
2.6 kW 230V 1 phase, 1 1/4” connection with O-ring seal
Adjustable: Electric output can be reduced by cutting one bridge on the element.
Thermostat: Adjustable 40~70°C(preset 60°C)
Safety cut-off: 98°C
Electric central:
Internally connected from factory. Splash proof IP21.
For installation in sanitary rooms special regulations apply.