Installing the unit
Installation of the indoor unit
The indoor unit should be installed indoors and meet the following conditions.
Installation site should be sheltered from frost.
In area with suitable space for servicing.
A place with adequate ventilation.
Where there is no risk of leakage of flammable gases.
There is a provision for condensate drain and pressure relief valve blow-off.
The wall for installation is a flat, vertical and non-combustible wall, capable of supporting the operation
weight of the unit.
Installation space
Ensure to leave the appropriate space as indicated in the drawing.
Installation site should be secured with adequate ventilation so that the components of hydro unit will
not be damaged from overheating.
Before installing the indoor unit, fix the pattern sheet on the wall.
This sheet has a function to take correct position for the wall mounting bracket and screws.
300
500
200
≥1200
≥350
(Unit :mm)
<Pattern Sheet>