4. Troubleshooting
► Error Code
A3–3310
A3–3311
A3–3312
A3–3320
A3–3410
A3–3411
A3–3412
► Error message
Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists.
Sensor Failure: #A3-3311. Turn off then on. Call for service if the problem persists.
Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists.
The room temperature is not suitable for this set use. Please adjust room temperature
Sensor Failure: #A3-3410. Turn off then on. Call for service if the problem persists.
Sensor Failure: #A3-3411. Turn off then on. Call for service if the problem persists.
Sensor Failure: #A3-3412. Turn off then on. Call for service if the problem persists.
► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
•
A3–3310 / A3–3311 / A3–3312 / A3–3320 : Temperature function of the sensor is abnormal.
•
A3–3410 / A3–3411 / A3–3412 : Humidity function of the sensor is abnormal.
1) Enter SVC mode. Execute sensor test to check its operation.
(Diagnostics > Engine Diagnostics > Engine Test Routines > 109-0013 Outer Temperature )
2) Remove the left cover.
Measure the resistance value of the connector at both ends.
If the value is not in 47.5KΩ ~ 52.5KΩ (@ 25
℃
), replace the outer temperature/humidity sensor(
JC32–00015A
).
3) If the harness and sensor are normal, replace the main board(
JC92–02661A
).
Copyright© 1995-2013 SAMSUNG. All rights reserved.
4-87
Содержание MultiXpress M437x series
Страница 36: ...2 Product Specifications and Description Paper Path 2 22 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 56: ...2 Product Specifications and Description M4370 2 42 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 158: ...4 Troubleshooting 6 Close the right bottom door 4 22 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 343: ...5 System Diagram 5 System Diagram Copyright 1995 2013 SAMSUNG All rights reserved 5 1 ...