4. Troubleshooting
•
Diagnostics > Adjustment > Scan Area Adjustment > Manual Adjustment
Purpose
To correct image position and magnification of scanned images manually.
Operation Procedure
1) Choose one item from the table. There are three items to choose.
•
Image Position - Leading Edge (Unit : mm, Min/Max : -3.0/+3.0)
•
Image Position - Side Edge (Unit : mm, Min/Max : -3.0/+3.0)
•
Magnification - Vertical Direction (Unit : %, Scale: 0.1, Min/Max: 98.5/101.5)
2) Select one item and press the “Edit” button.
3) Change the adjustment value with arrow button.
4) Image Position (a, b) : If the current value is smaller than the specification, press “+”.
Otherwise, press “-”.
5) Magnification (c) : If the current value is smaller than the specification, press “-”. Otherwise,
press “+”.
6) Press the “OK” button to apply the new value to the system.
7) Copy the Scanner A/S Chart. Scanning must be occur from the DSDF.
8) To check the image position, compare the position of scale marks (a,b) of the chart to the
copy.
9) To check the magnification, compare the length of line “c” of the chart to the copy.
NOTE
Specification
•
a,b : 10, ± 1.5 mm
•
c: 190, ± 1.5 mm
Copyright© 1995-2013 SAMSUNG. All rights reserved.
4-63
Содержание MultiXpress M437x series
Страница 36: ...2 Product Specifications and Description Paper Path 2 22 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 56: ...2 Product Specifications and Description M4370 2 42 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 158: ...4 Troubleshooting 6 Close the right bottom door 4 22 Copyright 1995 2013 SAMSUNG All rights reserved ...
Страница 343: ...5 System Diagram 5 System Diagram Copyright 1995 2013 SAMSUNG All rights reserved 5 1 ...