5-3 Malfunction
Error status
Check
Solution
1. Check FUSE
1. Replace SMPS.
- F1(8A), F2(5A) OPEN.
- Refer to “4-12”
No Power
2. Check FUSE.
2. Measure the resi5V and GND.
- F3(250V/3A) OPEN.
(Engine board CN5-pin6 and CN5-
pin9). If find the short circuit, replace
the Engine board.
1. Check Fuser unit
To disassemble the Fuser unit,
- Thermostat open
refer to “4-5”.
- hallogen lamp defect
1. If the thermostat of the fuser unit
Normal : 110V version - 2~3
•
ÿ
is opened. replace it.
220V version - 5~6
•
ÿ
2. Check themistor wire assembly defect.
2. If the thermistor wire of the fuser unit
Internal Error 11
Normal : 2~400k
•
ÿ
is defected, replace it.
(Fuser Error)
3. Check SMPS
3. If the fuser unit is normal,
- CN2 conection on SMPS
replace SMPS.
- Fuse(F2) open
- Defect of component related to Fuser
control.
4. Check Engine Board
4. If not normal operation after replacing
- CN7 connection
it, replace the engine board.
- Fuser control line:
Cn5-2 level (Lamp on : 0.2V, Lamp off:24V)
Check the Cover Open operation
1. Replace cover open Unit
1. Cover open unit defect
-Refer to “4-6”
Cover open
2. Cable damage and connection
2. Replace cover open switch
3. Engine board defect
assembly, and connect properly.
3. Replace the engine board.
Download Service Manual And Resetter Printer at http://printer1.blogspot.com
Содержание ML-7000N
Страница 14: ...Power Error Download Service Manual And Resetter Printer at http printer1 blogspot com ...
Страница 15: ...System Error Download Service Manual And Resetter Printer at http printer1 blogspot com ...
Страница 16: ...Engine Error Self Test Error Download Service Manual And Resetter Printer at http printer1 blogspot com ...