2. Product Specifications and Description
2) Development
This printer uses a dual-component development system and has a imaging unit (which is included in the drum unit). The
new unit contains 200g of magnetic toner carrier that is supplied to the magnetic roller [A] by the two mixing augers [B] and
is attracted onto the surface of the roller. The diameter of the magnetic roller is 18.2 mm.
The imaging unit has a TC (Toner Concentration) Sensor that is used for controlling toner density range. The imaging unit is
equipped with a CRUM in which some information about the imaging unit is stored.
[A] Ma g ne tic Ro lle r
[B]
Mixing
Aug e r
[C] TC
S e ns o r
[B] Mixing Aug e r
Two mixing augers [B] circulate the developer forward and backward to mix the carrier and toner well.
This job occurs at the following times:
•
During TC calibration
•
During development job
Copyright© 1995-2016 SAMSUNG. All rights reserved.