6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
6. Self Diagnosis & Trouble Shooting
To do list
231
PROBLEM
Trouble
Shooting Step 1
Trouble Shooting
Step 2
Possible Causes
SOLUTION
Nothing
coming
out when
pressing the
Sparkling
Water
Dispenser
Lever
Water coming out
when pressing
the Water
Dispenser Lever
Check it at the Display
Function of Load
Condition Mode.
: Displaying that the
Water Fill-Up is not
detected (R-10-
ⓔ
).
: Displaying that the
Water Empty is not
detected (R-10-
ⓕ
).
→ The Mixing Tank is
empty.
Without connecting
the Tap Water, run
the Sparkling Water
Production Mode.
And then, connect
the Tap Water.
(No Sparkling
Water is produced
after the Tap Water
and the CO2
Cylinder are
connected.)
1. Check if the CO2
Cylinder is connected
properly.
2. Reset the CO2
Cylinder by
pressing the Sparkling
Water button (
③
) for 3
seconds on the
Display Panel.
3. When pressing the
Sparkling Water Lever
after the Sparkling
Water Production is
completed, check if
the Sparkling Water
dispenses.