BASIC INSTALLATION TIPS

The gauge connection on the Samsung units is a 5/16” male, so an adapter is 
required to connect a standard North American set of R410A gauges to the 
Samsung unit.

R410A REFRIGERANT

(continued...)

UNIT LOCATION

High Wall units should be located a minimum of 4ft from the ground. Also, some 
of the indoor unit clearances listed in the specific unit installation manuals can 
be decreased to a minimum clearance of 2 inches from the ceiling to the top 
of the unit, while still maintaining unit performance and efficiency levels.

Indoor Unit:

Ensure that no obstacles are directly in front of the unit for a minimum distance 
of 

10-12ft on the MAX and Vivace 12,000 BTU units

20-25ft on the MAX and 

Vivace 24,000 BTU units

 and 

25-30ft on the MAX 36,000 BTU unit

This will prevent 

bounce back of the conditioned air and will ensure adequate airflow is 
maintained, keeping the indoor coil warm and allowing the system to run to 
full capacity when necessary.
If any system is prevented from running at full capacity regularly, whether it 
is from impeded airflow or over sizing, it will have an adverse affect on the 
system’s ability to properly return oil to the compressor. Over time this will cause 
inconsistent performance, error codes, and premature failure of components. 
Ceiling Cassette units must have a Minimum Distance of 5ft from the louver 
opening to any wall or other obstacle for the same reasons as listed above.

Ensure line set runs are adhered to, it is required that a minimum line set length 
of 10 ft. be maintained. Exceeding the published maximum line set length is 
not permitted, under any circumstance. 

Outdoor Unit:

Since these units are heat pumps, you should raise the outdoor unit 4-6” from 
the pad/ground to help drain the unit after a defrost cycle. Also, ensure the 
unit is capable of operating in desired ambient temperatures. As previously 
stated, if the outdoor coil temperature is allowed to drop below 10ºF, the 
system will lock out, not restarting until that temperature rises above 14ºF.

Minimum clearances of 6” behind and 24” in front of the outdoor unit must 
also be maintained. Enough clearance must be maintained from the sides to 
accommodate service of the unit. 

Also, keep in mind that since the expansion valve is located in the outdoor 
unit, the line set is merely an extension of the indoor coil and, although 
insulated, the longer the line set run is, the more likely there will noticeable loss 
of capacity. 

Содержание max mini-split units

Страница 1: ...WWW SUNLIGHTSUPPLY COM Distributed by BASIC TECHNICAL INFORMATION FOR SAMSUNG MAX MINI SPLIT UNITS...

Страница 2: ...0 16 oz ft over 25 ft CHARGE FOR LINE RUN LENGTHS Length 25 35 45 50 Added Charge oz 0 1 6 3 3 4 0 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconnecting Wir...

Страница 3: ...OR LINE RUN LENGTHS Length 25 35 45 55 65 75 85 95 98 Added Charge oz 0 1 6 3 2 4 8 6 4 8 0 9 6 11 2 11 68 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconnec...

Страница 4: ...LINE RUN LENGTHS Length 25 35 45 55 65 75 85 95 98 Added Charge oz 0 4 3 8 6 12 9 17 2 21 5 25 8 30 1 32 25 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconne...

Страница 5: ...quired to control MAX models with Samsung central control options upper level control Includes sub PCB 4 crimp wire connectors wire harness and sub PCB cover sub PCB Wire Harness sub PCB 1 With the po...

Страница 6: ...ntly pull this wire upward and out of the unit 3 Connect the PCB to the PCB wire harness a and to the sub PCB wire harness b NOTE the sub PCB wire harness is included with the wired controller a b 4 R...

Страница 7: ...red controller wires already installed pull the wires through the front of the indoor unit Cut the 2 small plastic connectors off the ends of the sub PCB wire harness the ends of the red blue and yell...

Страница 8: ...CAN BE EXPECTED DOWN TO 0 F OUTDOOR TEMPERATURE PLEASE NOTE THAT IF A PROLONGED OFF CYCLE IS EXPERIENCED IN OUTDOOR TEMPERATURES BELOW 10 F THE UNIT MAY NOT RESTART UNTIL THE TEMPERATURE RISES ABOVE...

Страница 9: ...an adverse affect on the system s ability to properly return oil to the compressor Over time this will cause inconsistent performance error codes and premature failure of components Ceiling Cassette...

Страница 10: ...Distributed by...

Отзывы: