Error items and Diagnostic Codes
Error Display
Trigger
Action Taken
Delicate
Dryer
Tumble
Dryer
1 tC
tC
The thermistor1 resistance is very low
or high.
- Check for a clogged lint screen.
- Check if the vent system is restricted.
- Check the thermistor resistance.
1 tC5
tC5
The thermistor2 resistance is very low
or high.
- Check for a clogged lint screen.
- Check if the vent system is restricted.
- Check the thermistor resistance.
1 dC
dC
The dryer is running with the door
open.
- Check the door, and run the dryer again.
- Check if the door sensor unit is loose or short.
-
dF
Incorrect door switch.
- Check if the door sensor unit is loose or short.
1 bC2
bC2
Incorrect button state.
- Check if the display PCB is loose or short.
1 FC
FC
Invalid power source frequency.
- Check if you are using regular power source
frequencies.
- Check the power frequency sensor circuit.
5. Test Mode & Error Check
“
This document can not be used without Samsung's authorization”
34