SAMSUNG Confidential
MODEL
LSC460HJ03
Doc. No
Page
40 / 42
3.3 The control PBA and the Source PBA
(a) The gaps between the source PBA and the other parts and the control PBA and other parts should
be considered to avoid the damage on electrical parts by the static electricity and the external
forces. If the material of shielding part is metal, the insulation method is recommended.
(b) Confirm the status of insulation tape since the inappropriately attached insulation tape can cause
the damage on the parts of product if the insulation tape for the insulation of part of PBA is
attached inconsecutively due to the inappropriate design or the error occurred during the process.