SAMSUNG Confidential
MODEL
LSC460HJ03
Doc. No
Page
10 / 42
Note (11) Gamma Variation between Center and Left (or Right)
Gamma measured at 10cm point from the left & right side is more less than 0.14 than Gamma
measured at Center
(Gamma measured at 10cm of the P-4 & P-6 is more less than 0.1 than Gamma measured at P-5)
Note (12) Management Criteria of ACC Linearity
Note (13)
White Color Coordinate Uniformity
of 9 points (Test pattern: The full white)
255Gray Wx/Wy value basis (a module unit basis)
a. Color coordinate differences are less than 15/1,000 at
Any Point above 30Gray and 255Gray
b.
When Wx/Wy coordinates reverse at 0Gray, it permits
an once intersection under, 30Gray
Wx, uni
= Wx max-Wx min
Wx max : The maximum Wx
Wx min : The minimum Wx
Wy, uni
= Wy max-Wy min
Wy max: The maximum Wy
Wy min: The minimum Wy