98
Each receiving card is connected with one monitoring card by default. Click
to pop up with the interface below. Please set the number of receiving cards
(0 or 1) according to the actual situation.
Click
to restore the default values immediately.
l Connect to Monitoring Card
If this option is selected, the monitoring data of the monitoring card will be displayed. The
Connect to Monitoring Card
and
Connect to Smart Module
options cannot be selected
at the same time.
l Connect to Smart Module
If this option is selected, the monitoring data of the smart module will be displayed. The
Connect to Monitoring Card
and
Connect to Smart Module
options cannot be selected
at the same time.
l Refresh Humidity
If this option is selected, the humidity within the cabinets will be under monitoring.
l Refresh Smoke
If this option is selected, the smoke within the cabinets will be under monitoring.
l Refresh Ribbon Cable
If this option is selected, the status of the ribbon cable will be under monitoring.
l Refresh status of Cabinet-Doo
r
If this option is selected, the open/close status of the cabinet doors will be under
monitoring.
l Refresh Fan
If this option is selected, the fans status will be under monitoring.
− Set fan quantity uniformly: If for every cabinet, the number of fans to be
monitored is the same, select this option and set the fan number in the box to the right of
this option.
− Set fan quantity individually: If the numbers of fans to be monitored are different
from one cabinet to another, select this option and click the
Setting
button to set the fan
numbers for each cabinet.
l The numbers of power supplies on each monitoring card are equal to each other
If this option is selected, the power supplies on the monitor board will be under monitoring.
− Every monitoring card has the same number of power supply: If for every monitor
board, the number of power supplies to be monitored is the same, select this option and
set the power supplies number in the box to the right of this option.
Set power supply quantity individually is separately set on every monitoring card: If the
numbers of power supplies to be monitored are different from one monitor board to
another, select this option and click the
Setting
button to set the power supplies numbers
for each cabinet.
Содержание LH067XATSAC
Страница 16: ...16 3 2 Product Appearance ...
Страница 17: ...17 XAT6 7 XAT10 XAT16 ...
Страница 18: ...18 3 3 Product design Decomposition chart ...
Страница 19: ...19 Assembly drawing ...
Страница 20: ...20 3 4 Product main components Module Power Supply Receiving card DC output cables 9 pcs Flat cables 9 pcs ...
Страница 45: ...45 Installation of cabinets Fixing of connect plate ...