104
10.3 Replacement steps
Front Service:
Module
Power off the cabinet where the module is in
Remove the module from front by front service tool as shown below
Remove the DC power cable and flat cable from the bad module, and then take off the
bad module from cabinet by hand as shown below
Bring a new module, connect the DC power cable and flat cable into the new module
Put the new module on the cabinet and then install it into cabinet by front service tool as
shown below
Power on the cabinet.
After replacing modules, the customer should update the calibration data for that module
in the receiving card. Operation details are shown in chapter 9.9. All the spare module
have a serial number as S-1, S-2, S-3 etc.