1-3
1-2. Servicing Precautions
Warning
• An electrolytic capacitor installed with the wrong polarity might explode.
Caution
• Before servicing units covered by this service manual, read and follow the Safety Precautions section of
this manual.
Note
• If unforeseen circumstances create conflict between the following servicing precautions and any of the
safety precautions, always follow the safety precautions.
1. Servicing precautions are printed on the cabinet. Follow them.
2. Always unplug the unit’s AC power cord from the AC power source before attempting to: (a) Remove or reinstall any
component or assembly, (b) Disconnect an electrical plug or connector, (c) Connect a test component in parallel with an
electrolytic capacitor.
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used. The
internal wiring may be clamped to prevent contact with thermally hot components. Reinstall all such elements to their original
position.
4. After servicing, always check that the screws, components and wiring have been correctly reinstalled.
Make sure that the portion around the serviced part has not been damaged.
5. Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels, input
terminals and earphone jacks).
6. Insulation Checking Procedure: Disconnect the power cord from the AC source. Connect an insulation resistance meter
(500V) to the blades of the AC plug.
7. The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be greater
than 1 megohm.
8. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-
state heat sinks are correctly installed.
9. Always connect a test instrument’s ground lead to the instrument chassis ground before connecting the positive lead; always
remove the instrument’s ground lead last.
Warning
• First read the “Safety Precautions” section of this manual. If some unforeseen circumstance creates a
conflict between the servicing and safety precautions, always follow the safety precautions.
Содержание HW-T450
Страница 11: ...Product Specifications 2 3 Accessories 2 3 ...
Страница 13: ...View Exploded Disassembly and Reassembly ...
Страница 21: ...4 6 Troubleshooting 4 1 5 In case of key is not working Diagnostics ...
Страница 22: ...In case of VFD is not working 4 7 Troubleshooting 4 1 6 Diagnostics ...
Страница 23: ...4 8 Troubleshooting 4 1 6 In case of USB is not working Diagnostics ...
Страница 24: ...4 9 Troubleshooting 4 1 7 In case Bluetooth is not working Diagnostics ...
Страница 26: ...4 11 Troubleshooting 4 3 Initialization Update 4 3 1 Set Initialization method ...
Страница 27: ...4 12 Troubleshooting 4 3 Initialization Update 4 3 2 How to check firmware version ...
Страница 28: ...4 13 Troubleshooting 4 3 3 USB Update procedure ...
Страница 29: ...5 1 PCB Diagram 5 PCB Diagram 5 1 Wiring Diagram Pin Connection ...
Страница 30: ...5 2 PCB Diagram 5 2 MAIN PCB Top ...
Страница 31: ...5 3 PCB Diagram 5 3 MAIN PCB Bottom ...
Страница 32: ...5 4 PCB Diagram 5 3 1 Pin Connection ...
Страница 33: ...5 5 PCB Diagram 5 3 2 Test point wave form ...
Страница 34: ...5 5 PCB Diagram 5 3 3 Test point wave form ...
Страница 35: ...5 5 PCB Diagram 5 3 4 Test point wave form ...
Страница 36: ...5 5 PCB Diagram 5 3 5 Test point wave form ...
Страница 37: ...5 6 PCB Diagram ...
Страница 38: ...PCB Diagram 5 4 Main board PCBA Bar 5 7 Top Bottom ...
Страница 39: ...Top PCB Diagram 5 5 Power PCBA Bar 5 8 Bottom ...
Страница 40: ...PCB Diagram 5 6 VFD Board PCBA Bar 5 9 Top Bottom ...
Страница 41: ...PCB Diagram 5 7 KEY Board PCBA Bar 5 10 Top Bottom ...
Страница 42: ...PCB Diagram 5 7 AMP PCBA Sub 5 10 Top Bottom ...
Страница 43: ...Exploded Views and Parts List 1 HW T450 ZA ZZ01 Exploded View 1 ...
Страница 46: ...Exploded Views and Parts List 1 HW T450 ZC ZZ01 Exploded View 1 ...
Страница 49: ...Exploded Views and Parts List 1 HW T450 ZP ZZ01 Exploded View 1 ...