43
Preparations
1
1 Preparations
Manual Lamp (Backlight) Control
z
Function
The "Manual Lamp(backlight) "of a product can be changed using a PC.
z
Get "Manual Lamp" Status
z
Set "Manual Lamp"
"LampValue" : Manual Lamp value to be set on a product. (0 ~ 100)
z
Ack
"LampValue" : Manual Lamp value to be set on a product. (0 ~ 100)
z
Nak
"ERR": A code showing what error has occurred.
0 : Check Sum Error
1 : Not Supported Command
Header
Command
ID
Data length
Checksum
0xAA
0x58
0
Header
Command
ID
Data length
Data
Checksum
0xAA
0x58
1
"LampValue"
Header
Command
ID
Data length
Ack/Nak
r-CMD
Val1
Checksum
0xAA
0xFF
3
‘A’
0x58
"LampValue
"
Header
Command
ID
Data length
Ack/Nak
r-CMD
Val1
Checksum
0xAA
0xFF
3
‘N’
0x58
"ERR"