GY15MS*/GY17MS*
3-1
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
GY15MS*/GY17MS* TFT-LCD monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.
3. R/Cover opening jig : BH81-00001A
3-1-1 GY15MS*
1. Place monitor face down on cushioned table.
Remove 2 screws from grip on the stand and
remove signal cable.
CAUTION : Always securely hold the stand
to remove a screw. Failure to do so may cause
the stand to topple or fall onto your feet.
2. Remove 2 screws from the rear cover. Insert
the opening jig into the grooves at each side
and press until it clicks.
3. Open the rear cover and remove 2 screws
from the shield.
4. Disconnet function cable and audio board
cable. Pull the shield-PCB.
5. Disconnect inverter cable and LVDS cable.
(see illustrations)
Содержание GY15MS series
Страница 8: ...2 Product Specifications 2 4 GY15MS GY17MS Memo ...
Страница 16: ...4 Alignments and Adjustments 4 4 GY15MS GY17MS Memo ...
Страница 21: ...5 Troubleshooting GY15MS GY17MS 5 5 WAVEFORMS 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 22: ...Memo 5 Troubleshooting 5 6 GY15MS GY17MS ...
Страница 24: ...6 Exploded View Parts List 6 2 GY15MS GY17MS 6 2 GY17MS ...
Страница 42: ...Memo 7 Electrical Parts List 7 18 GY15MS GY17MS ...
Страница 43: ...GY15MS GY17MS 8 1 8 Block Diagram 8 1 GY15MS ...
Страница 44: ...8 Block Diagrams 8 2 GY15MS GY17MS 8 2 GY17MS ...
Страница 54: ...11 Schematic Diagrams 11 6 GY15MS GY17MS CONFIDENTIAL Memo ...