42
4. Troubleshooting
4-2 Electrical Malfunction
LF radiant element
(No heating or
abnomal working)
* Disconnect power
* Check the LF infinite switch
*Check whether harness connected
wire and the state of LF infinite
switch are in normal
No
Fig.5 The drawer of connected wire of Harness
Ok
Ok
Ok
Ok
*Check whether harness in
terminal of switch has been
loosen or disconnected.
*Weld with terminal not to be misconnected
if harness is disconnected from terminal
on switch.
*Tighted terminal of harness by
compressing not to be loosen.
(Continued)
Ok
*Check whether harness is connected with
cooktop has been loosen or damaged.
*Check the element of LF Radiant on cooktop.
Next Page
END
END
LF Infinite switch
LF Infinite switch
*Single element Left Front(LF)
Position Color
3-L1 black+black
5-L2 red+red
4-H2 blue
2-P blue
1-H1 gray
Remark
240V, 2500W
single switch
Invensys Co.
1-H1
1-H1
2-P
2-P
4-H2
4-H2
5-L2
5-L2
3-L1
3-L1
Содержание FCQ321HTUW
Страница 9: ... 2 Specifications 2 3 Accessory Item Description Code No Q ty Rack Flat DG75 01001A 2 ...
Страница 30: ...30 4 Troubleshooting 4 1 Failure Display Codes Safety error ...