Option item
Input
unit
SEG1
SEG2
SEG3
SEG4
Function
Remarks
Current
Restriction
Main
PCB
0
3
0
0
100%
Default
When
restriction
option is set,
cooling and
heating
performance
may decrease
0
1
95%
0
2
90%
0
3
85%
0
4
80%
0
5
75%
0
6
70%
0
7
65%
0
8
60%
0
9
55%
1
0
50%
1
1
No restriction
Outdoor
Setting
15
NOTE:
•
Press and hold the
K1 button to reset
values to previous
settings.
•
Press and hold K4 to
restore to factory
default settings.
•
Once you release K4
for factory default
wait until the system
resets and starts the
tracking process.
Then press and hold
the K2 button to
save the setting.
•
Press K3 at any time
to exit