Disassembly and Reassembly _ 21
Part
Figure
Description
Assy Sump
Preparation:
• Disassemble the baskets, nozzles, duct nozzle
& storm wash nozzle.
• Disassemble the frame left & the shutter &
bracket front lower.
- Refer to each disassembly section.
1. Remove the parts which are connected to the
Assy sump.
- connectors, drain pump, screws
2. Remove the three (3) screws & holders in Assy
sump.
Pull out the holders using a pair of needle nose
pliers. At the same time, press the tab at the
top of the holder using a screwdriver.
Assy Cover
nozzle
3. Push the Assy sump using your hands toward
the inside carefully.
Caution
Remove the water from the sump assembly
before removing the sump assembly. Failure to
do so will cause to be released onto the floor.