Installation
Installation
English
22
STEP 3
Connect the electrical wiring
First, read through the “
” section, and then follow these steps.
3-wire system
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
1.
Loosen or remove the center terminal
block.
2.
Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw
of the terminal block. Tighten the
screws.
3.
Connect the other wires to outer
terminal block screws. Tighten the
screws.
4.
Tighten the strain relief screws.
5.
Insert the terminal block cover into the
rear panel of the dryer. Then, secure
the cover with a hold-down screw.
CAUTION
• To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
DV5500M_03381G_EN.indd 22
12/26/2016 11:02:01 AM
Содержание DVE45M5500P
Страница 1: ...Dryer User manual DVE G 45M5500 DV5500M_03381G_EN indd 1 12 26 2016 11 01 56 AM...
Страница 59: ...Memo DV5500M_03381G_EN indd 59 12 26 2016 11 02 13 AM...
Страница 61: ...S che linge Manuel d utilisation DVE G 45M5500 DV5500M_03381G_CFR indd 1 12 26 2016 11 08 04 AM...
Страница 119: ...M mo DV5500M_03381G_CFR indd 59 12 26 2016 11 08 18 AM...
Страница 121: ...Secadora Manual del usuario DVE G 45M5500 DV5500M_03381G_MES indd 1 12 26 2016 1 09 41 PM...
Страница 179: ...Notas DV5500M_03381G_MES indd 59 12 26 2016 1 10 06 PM...
Страница 180: ...Notas DV5500M_03381G_MES indd 60 12 26 2016 1 10 06 PM...
Страница 181: ...Notas DV5500M_03381G_MES indd 61 12 26 2016 1 10 06 PM...