English
31
English
Installation check codes
Check code
Meaning
Solution
0
Vent condition is good.
C80 (C8)
About 80 % of the vent is clogged.
(This may decrease the drying
performance.)
1.
Clean the lint filter.
2.
Check your vent condition.
(Refer to the “
Ducting
requirements
” section)
* You must take measures (such as
cleaning) through expert personnel.
C90 (C9)
Over 90 % of the vent is clogged.
(This may lead to poor drying
performance or cause malfunction)
Ct
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C)) and
therefore vent blockage cannot be
detected.
Leave the dryer at room
temperature (41~95 °F (5~35 °C))
for an hour and check again.
tC
Temperature sensor error
Contact a service center.
C1
Unit is detecting items inside the
drum or there is an error on the dry
sensor.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
dC
Unit is detecting door is open
Close the door properly and check
again.
If the problem continues, contact a
service center.
9C1
Abnormal voltage detected
Check the power connection. (Refer
to the “
Connect the electrical wiring
”
section)
If the problem continues, contact a
service center.
HC
Detection of abnormal temperature
in drum.
Check the power connection.
Check the vent condition if the
problem continue, contact a service
center.
DV6900B_LED_WEB_Vent_EN.indd 31
2022/5/16 12:25:39
Содержание DV25B6800E Series
Страница 1: ...Dryer User manual DV25B6800E DV6900B_LED_WEB_Vent_EN indd 1 2022 5 16 12 25 34 ...
Страница 61: ...Memo DV6900B_LED_WEB_Vent_EN indd 61 2022 5 16 12 25 46 ...
Страница 63: ...Sèche linge Manuel d utilisation DV25B6800E DV6900B_LED_WEB_Vent_CFR indd 1 2022 5 14 16 35 20 ...
Страница 123: ...DV6900B_LED_WEB_Vent_CFR indd 61 2022 5 14 16 35 31 ...
Страница 125: ...Secadora Manual del usuario DV25B6800E DV6900B_LED_WEB_Vent_MES indd 1 2022 5 14 16 45 54 ...
Страница 185: ...DV6900B_LED_WEB_Vent_MES indd 61 2022 5 14 16 46 06 ...