Before installation
English
14
English
Ducting requirements
Recommended
Use only for short-run installation
Weather hood
type
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Rigid
0
80 ft. (24.2 m)
60 ft. (28.3 m)
1
60 ft. (28.3 m)
45 ft. (13.7 m)
2
45 ft. (13.7 m)
35 ft. (10.7 m)
3
35 ft. (10.7 m)
25 ft. (7.6 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
DV6900B_LED_WEB_Vent_EN.indd 14
2022/5/16 12:25:35
Содержание DV25B6800E Series
Страница 1: ...Dryer User manual DV25B6800E DV6900B_LED_WEB_Vent_EN indd 1 2022 5 16 12 25 34 ...
Страница 61: ...Memo DV6900B_LED_WEB_Vent_EN indd 61 2022 5 16 12 25 46 ...
Страница 63: ...Sèche linge Manuel d utilisation DV25B6800E DV6900B_LED_WEB_Vent_CFR indd 1 2022 5 14 16 35 20 ...
Страница 123: ...DV6900B_LED_WEB_Vent_CFR indd 61 2022 5 14 16 35 31 ...
Страница 125: ...Secadora Manual del usuario DV25B6800E DV6900B_LED_WEB_Vent_MES indd 1 2022 5 14 16 45 54 ...
Страница 185: ...DV6900B_LED_WEB_Vent_MES indd 61 2022 5 14 16 46 06 ...