Troubleshooting _ 27
System check mode
Special test mode:
• While in Power Off, pressing the Dry Level + Power buttons simultaneously will put the dryer into the System Check
mode
• “t2” will display.
• System Check Mode Progress
t2 mode Function Performed Start/Pause Motor(CW) Relay On → Heater Relay On → Heater Relay Off → Motor(CW)
Relay Off (Circulation)
4-3. TROuBLE DIAGNOSIS
As the micom dry machine is configured for the complicate structure, there might be a service call.
The below information is prepared for exact trouble diagnosis and suitable repair guide.
Caution for the repair and replacement
Please follow below instruction for the trouble diagnosis and parts replacement.
1. As some electronic components can be damaged by static
electricity from the resin part of dryer or the human body,
remove the potential difference of the human body and the
dryer by contacting the power plug before you start working
at PCB.
2. Since AC220~240V is applied to the triac T1 and T2 on P.C.B, the electric shock may occur by touching. Be careful
the strong and weak electricity are mixed each other.
3. As the P.C.B assembly is designed for no trouble, do not replace the P.C.B assembly by the wrong diagnosis and
follow the procedure of the trouble diagnosis when the micom is not operated normally.
No
Problem
What to do
1
Will Not Start or Run
•
All wires are hooked up to their corresponding terminals.
•
Is the dryer is plugged in.
•
Blown fuse or circuit breaker.
•
Is the Door switch functional...door closed. Check for error code 3 (See Table for code
definition).
•
Start/Pause rotary selector dial functional.
•
Is the control Board operational.
•
Belt off or broken and Belt Cut-off Switch operates.
•
Is the motor functional.
•
Check motor winding resistance: 2.88ohms between pin #3 and 4, 3.5ohms between pin #4
and 5.
2
Motor runs/ tumbler will not
turn
•
Belt off or broken/damaged.
•
Idler tension spring too weak or stretched.
•
Idler pulley jammed or stuck.
3
Runs a few minutes and then
stops
• Lint buildup around drive motor.
• Low voltage present.
• Blower impeller blocked in blower housing.
• Check the actuator of motor.