Causes
Check Point
water valve, water level sensor / hose , main PBA
ㆍ
Water valve defective
ㆍ
Water level sensor defective
ㆍ
Main PBA defective
Symptom
ㆍ
Water is supplied continuously.
Step 1 :
Water Valve
!
If water is supplied on Power off status, replace the water valve.
#5. Water Supply Problem
5-2. No Stop Water Supplying
Step 2
: Water Level Sensor
!
Check the connections to the Water-level sensor.
! ".#$%&!
Step 3
: Main PBA
!
Power on and then check voltage of the water valve.
(
If the voltage value is approximately AC 120V,
even though the valve is not working, Replace Main PBA.
!
Check the connections to the Water-level sensor.
"
Check for the operation of the Water-level sensor float.
If it is faulty, replace the assembly case sensor &
remove foreign material from the float
If it is normal, replace the Main PBA assembly.