3-15
3. Disassembly and Reassembly
Part
Photo
Description
CAPACITOR
SUMP ASS’Y
Caution
Take care when holding and removing the clamp
with a tool, as it may bounce and harm you.
Ƒ
Separate housing L/R
Ƒ
Separate tub ass’y
Ƒ
Separate top table ass’y
3) You can remove the SUMP ASS’Y.
22.Capacitor
Ƒ
Separate housing R
Ƒ
Separate top table ass’y
1) Remove the two (2) CAPACITOR connectors.
2) Push the hooks fixing CAPACITOR and remove it.
Be careful to avoid breaking them, because they are
connected with a hook.
23. Sump ass'y
* If necessary, rub with a dry towel remainning water
water in order to keep clean SUMP ASS’Y.
* In assembling, confirm the assembly condition of
contact sump gasket
* When sump gasket is deformation, you must change
new one
Ƒ
Separate main pcb ass’y
1) Remove the all connectors and clamps connected with
SUMP ASS’Y on both side of the it.
2) Remove the two (2) screws holding SUMP ASS’Y
(C/PUMP DAMPER) in place.