3-16
3. Disassembly and Reassembly
Part
Photo
Description
DRAIN PUMP
ASS’Y
CIRCULATION
PUMP ASS’Y
24. Drain pump ass'y
Ƒ
Separate housing L/R
Ƒ
Separate main pcb ass'y
Ƒ
Separate top table ass’y
Ƒ
Separate tub ass'y
1) Remove the two (2) DRAIN PUMP connectors.
2) Remove the five (5) screws holding DRAIN PUMP
ASS’Y in place.
Ƒ
Separate sump ass'y
3) Remove the DRAIN PUMP ASS’Y.
25.Circulation pump ass'y
Ƒ
Separate housing L/R
Ƒ
Separate main pcb ass'y
Ƒ
Separate top table ass’y
Ƒ
Separate tub ass'y
Ƒ
Separate sump ass'y
1) Remove the screw holding GROUND WIRE in place.
2) Remove the DOUBLE WIRE SCREW CLAMP holding
the C-PUMP OUTLET HOSE in place.
5) You can remove the CIRCULATION PUMP ASS’Y.
Caution
* If necessary, rub with a dry towel remainning water
water in order to keep clean SUMP ASS’Y.
* In assembling, confirm the assembly condition of
contact sump gasket
* When sump gasket is deformation, you must change
new one
Caution
* If necessary, rub with a dry towel remainning water
water in order to keep clean SUMP ASS’Y.
* In assembling, confirm the assembly condition of
contact sump gasket
* When sump gasket is deformation, you must change
new one
Содержание DMS300 series
Страница 8: ......
Страница 48: ...5 4 5 Exploded Views and Parts List 5 3 TUB ASS Y DMS500 400 300 301TR ...
Страница 50: ...5 6 5 Exploded Views and Parts List 5 4 BASE ASS Y DMS500 400 300 301TR ...
Страница 52: ...5 8 5 Exploded Views and Parts List 5 5 SUMP ASS Y DMS500 400 300 301TR ...
Страница 54: ...5 10 5 Exploded Views and Parts List 5 6 ASSY RACK DMS500 400 300 301TR DMS500 400 301TR DMS300TR DMS TR 22 23 ...