background image

safety information

 

_07

ENGLISH

Check for damage on delivery. If damaged, do not install the air conditioner and call 

the place of purchase immediately. 
Insert the dust filter before operating the air conditioner. 

• 

If there is no dust filter inside the air conditioner, accumulated dust may shorten the life of the air 

conditioner and cause electricity waste.

Keep indoor temperatures stable and not extremely cold, especially where there are 

children, elderly or disabled people.
Clean the dust filter every 2 weeks. Clean the filter more frequently if the air 

conditioner is operated in dusty areas.
The packaging material and used batteries of the remote controller (optional) must be 

disposed of in accordance with the national standards. 
The refrigerant used in the air conditioner must be treated as chemical waste. Dispose 

the refrigerant following national standards. 
Have a qualified service technician install the air conditioner and perform a trial 

operation.
Firmly connect the drain hose to the air conditioner for proper water drainage.
Install the outdoor unit where operating noise and vibration will not disturb your 

neighbor and in a well-ventilated area with no obstacle.

• 

Potential risk of malfunction.

• 

Operating noise may disturb your neighbor.

Make sure that children take precautions against access to the air conditioner and 

they do not play with the unit.
When using a wireless remote control, the distance should not be more than 7 meters 

from the air conditioner.
If the remote control is not used for a long period of time, remove the batteries to 

prevent leakage of electrolyte.
When cleaning the outdoor unit, touch the heat exchanger radiator fins with extreme 

care.

• 

Wearing thick gloves can protect your hands.

Make sure that the condensed water dripping from the drain hose runs out properly 

and safely.
Store the operation and installation manual in a safe location and remember to hand it 

over to the new owner if the air conditioner is sold or transferred.
All the materials used for the manufacture and packaging of the air conditioner are 

recyclable.
After completing the installation, always carry out a functional test and provide the 

instructions on how to operate the air conditioner to the user. 
The appliance is not intended for use by young children or infirm persons without 

supervision: Young children should be supervised to ensure that they do not play with 

the appliance.
Clean the air conditioner after the inner fan stops operating. 

• 

Potential risk of injury or electric shock.

Inspect the condition, electric connections, pipes and external case of the air 

conditioner regularly by a qualified service technician.
Do not open doors and windows in the room being cooled during operation unless 

necessary.
Do not block the air conditioner vents. If objects block the air flow, it may cause unit 

malfunction or poor performance.
Make sure there are no obstacles under the indoor unit. 

• 

Potential risk of fire or loss of property.

Make sure that there are no obstacles or covers that block the air conditioner.  

Allow sufficient space for air circulation.

• 

Insufficient ventilation may result in poor performance.

Содержание DC24ETSA

Страница 1: ......

Страница 2: ...your own air conditioner Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advance...

Страница 3: ...pt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock Call the contact center for help R...

Страница 4: ...sult the contact center Consult the place of purchase or a contact center to disassemble or reinstall the air conditioner Potential risk of unit malfunction water leakage electric shock or fire Consul...

Страница 5: ...ect the air conditioner from power supply before it is repaired or disassembled CAUTION SIGNS Connect the refrigerant tubes first then the electrical lines when installing the unit Always disassemble...

Страница 6: ...l reception error may occur due to the ballast of the lighting apparatus For maximum safety installers should always carefully read the following warnings Do not install the air conditioner in followi...

Страница 7: ...onditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with...

Страница 8: ...ble and the connection cord of the indoor and outdoor units in the protection tube Connect the power cable to the auxiliary circuit breaker You must keep the cable in a protection tube Keep distances...

Страница 9: ...your air conditioner CLEANING AND MAINTAINING THE AIR CONDITIONER 12 12 Cleaning the filter 12 Slim duct type 13 MA duct type 14 Maintaining your air conditioner 14 Periodical checks 15 Internal prot...

Страница 10: ...ol or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner SLIM DUCT TYPE MA DUCT TYPE Your air conditioner may look slightly differe...

Страница 11: ...The air conditioner stops heating The air conditioner will operate automatically in De ice mode for 10 minutes The steam produced on the outdoor unit in De ice mode is safe No intervention is required...

Страница 12: ...is cleaned with a vacuum or by hand washing Slim duct type 1 Way 1 Slide out the Air filter on the rear side panel to the right side Way 2 Take out the Air filter from the panel 2 Clean the Air filte...

Страница 13: ...area For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a ventilated area 3 Way 1 Insert the filter b...

Страница 14: ...ndoor unit Clean the air filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the...

Страница 15: ...when the heat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air condi...

Страница 16: ...e for cooling model The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Ch...

Страница 17: ...IF OUT OF CONDITIONS INDOOR OUTDOOR COOLING 21 C to 32 C 21 C to 54 C 80 or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor DRYING 21 C to...

Страница 18: ...UESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT Turkey 444 77 11 www samsung com tr SOUTH AFRICA 0860 SAMSUNG 726 7864 www samsung com za U A E 800 SAMSUNG 726 7864 8000 4726 www samsung com a...

Страница 19: ...Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register Duct Type Series Slim duct MA duct DC18ET DC24ET DC30ET D...

Отзывы: