Safety Precautions

The following safety precautions must be taken when using your air conditioner.

Users of this product are cautioned not to attempt repair of this product at their
own discretion. Instead, they are requested to directly contact a designated
service center or the outlet at which the product was purchased. 
Never spill any kind of liquid into the unit. Should this happen, unplug or main 
switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may 
be damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off 
the breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times: 
Do not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries. (If applicable)
When using a wireless remote control, the distance should not be more than 7
meters from the air conditioner. (If applicable)

WARNING

D

URING OPERATION

Risk  of  electric  shock. 

• 

Can  cause  injury  or  death. 

• 

Disconnect  all

remote  electric  power  supplies  before  servicing,  installing  or  cleaning. 

• 

This must be done by the manufacturer or its service agent or a similar

qualified person in order to avoid a hazard.

The air conditioner must be plugged into its own specific power source, which 
must be installed in compliance with national wiring,earthing and safety 
regulations.

If the power cord is damaged in any way, it must be replaced by the manufacturer  

or its service agent or a similarly qualified person in order to avoid a hazard.

This device must be installed according to the national electrical rules.

The appliance must be installation that the plug should be easily accessible 

after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.

The breaker of the air conditioner should be all-pole switch; and the distance 

between its two contacts should be no less than 3.5mm. Such means for

disconnection must be incorporation in the fixed wiring.

Never store or ship the air conditioner upside down or sideways to avoid damage
to the compressor.
The appliance is not intended for use by young children or infirm persons without 
supervision: Young children should be supervised to ensure that they do not play
with the appliance.
Max current is measured according to IEC standard for safety and current is 
measured according to ISO standard for energy efficiency.

O

THERS

Before throwing out the device, it is necessary to pull back the battery cells and
get rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectly, refrigerant may blow out and come into contact with your skin,causing
injury. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally responsible manner.

D

ISPOSING OF THE UNIT

Register your product at

 

www.samsung.com/global/register 

Содержание DB98-17032A(5)

Страница 1: ...DB98 17032A 5 DB98 17032A E F Window type Room Air Conditioner Cool AW0605B AW0805B AW1005B AW1205B AW0695B AW0895B AW1095B AW1295B OWNER S INSTRUCTIONS AW109BB AW089DB AW109DB AW129BB AW129DB...

Страница 2: ...ower source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service ag...

Страница 3: ...Airing Your Room 9 Removing Excess Humidity 10 Adjusting the Air Flow Direction Horizontally 11 Adjusting the Air Flow Direction Vertically 11 PROGRAMMING YOUR AIR CONDITIONER Setting the On Timer 12...

Страница 4: ...mer setting button Fan speed adjustment button Remote control Energy Saver button Outer air flow blades up down orientation Ventilation lever Air outlet Air inlet Outside Air filter Inside Air outlet...

Страница 5: ...E 5 Remote Control Buttons Timer setting button Temperature adjustment buttons Fan speed adjustment buttons On Off button Sleep timer setting button Mode selection buttons Energy Saver button...

Страница 6: ...unit s features The booklet is organized as follows The following figures are shown on pages 4 and 5 Description of Each Component Remote control buttons They will help you find the buttons and under...

Страница 7: ...ote control on the battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of...

Страница 8: ...ioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will begin to cool after three minutes If the temper...

Страница 9: ...esired fan speed F1 F2 or F3 is displayed 3 To control the direction of the air flow refer to page 11 4 If the fan speed F1 F2 or F3 is not displayed on the control panel Press the button on the remot...

Страница 10: ...not displayed at the top of the control panel press the button on the control panel one or more times until it appears Result The unit beeps each time you press the button The air conditioner runs in...

Страница 11: ...ide Adjusting the Air Flow Direction Vertically The outer air flow blades can be adjusted to control the vertical air flow direction RECOMMENDATION When Cooling Adjust the blades to face Upwards Adjus...

Страница 12: ...time can be set between 1 and 24 hours Result Each time you press the button The time is adjusted by 1 hour and displayed on the control panel The unit beeps The operating time is displayed and decrea...

Страница 13: ...time can be set between 1 and 24 hours Result Each time you press the button The time is adjusted by 1 hour and displayed on the control panel The unit beeps The operating time is displayed and decre...

Страница 14: ...layed and decreased by 1 hour automatically to indicate the remaining time The air conditioner will be controlled as illustration below To cancel the timer press Sleep on the remote control or Sleep o...

Страница 15: ...ditioner to run in Dry mode do not press the button You cannot use the Dry mode in the energy saving mode To stop the energy saving mode press the button on the remote control or button on the unit ag...

Страница 16: ...or some other malfunction may happen if the heat exchanger freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods The following table...

Страница 17: ...not to use benzene solvent or other chemical products 5 Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period of time When cleaning the...

Страница 18: ...perate with the remote control Odors are permeating the room during air conditioning Check that you are pointing the remote control at the remote control sensor on the unit Replace the remote control...

Страница 19: ...l Specifications Model Power Supply Design and specifications are subject to change without notice 115V 60Hz AW0805B AW1005B AW1205B AW0895B AW1095B AW1295B AW0695B AW0605B AW109BB AW129BB AW089DB AW1...

Страница 20: ...mpressor during these existing four years is not included in the warranty All warranty repairs must be performed by a Samsung Authorized Service Centre Obligation of the Original Owner The original da...

Отзывы: