- 12 -
3-5 Replacement of the Assy-Induction Module
Assy-Induction
Module
Attention
If wire of Assy-Inverter Module(L,R) is connected to wrong Assy-Working Coil,
wrong cooking zone will be operated when costomer start the cook.
12. Remove the 1 screw at Motor
DC.(bottom side)
* screw-2 type : 6006-001170
(M4,L10,Ground screw)
13. Remove the 2 screws at Motor
DC.(upper side)
* ‘FM’ marking is carved at the
upper side.
* screw-3 type : 6002-001321
(M5,L10)
14. Replace the Motor DC.
screw-2
screw-2
screw-3
screw-3
screw-3
screw-3