Rev. 1.00
- 17 -
SRP-500
ESC c 4 n
[Name]
Select paper sensor(s)to stop printing
[Format]
ASCll
ESC c
4
n
Hex
18
63 34 n
Decimal 27
99 52 n
[Range]
0
≤
n
≤
255
[Description]
Selects the paper sensor(s) used to stop printing when a paper-end is
detected, using n as follows :
Bit
Off/On
Hex
Decimal
Function
Off
00
0
Paper roll near end sensor disabled.
0
On
01
1
Paper roll near end sensor enabled.
Off
00
0
Paper roll near end sensor disabled.
1
On
02
2
Paper roll near end sensor enabled.
2 - - -
Undefined
3 - - -
Undefined
4 - - -
Undefined
5 - - -
Undefined
6 - - -
Undefined
7 - - -
Undefined
[Notes]
The printer goes off-line after printing stops.
The paper roll near-end sensor is an option, therefore, if the paper roll near-end sensor
is enabled by this command when the sensor is not equipped, it does not stop printing.
The paper roll near-end sensor is enabled when either bit 0 or 1 is 1.
The paper roll end sensor is a sensor which is always used to make an effective to stop
printing.
[Default]
n = 0
ESC c 5 n
[Name]
Enable/disable panel buttons
[Format]
ASCII ESC c
5
n
Hex
1B
63
35 n
Decimal 27
99
53 n
[Range]
0
≤
n
≤
255
[Description]
Enables or disables the panel buttons.
When the LSB of n is 0, the panel buttons are enabled.
When the LSB of n is 1, the panel buttons are disabled.
[Notes]
Only the least significant bit of "n" is valid.
When the panel buttons are disabled, no buttons on the panel are usable.
If "disabled" is set, the paper feed switch no longer functions.
[Default]
n = 0