98
SAMSUNG ELECTRONICS
10-2-11 Compressor wire missing error/rotation error
Indoor display
7 SEG DISPLAY
DESCRIPTION
C467
Compressor wire missing errorr/rotation error
Outdoor display
Compressor wire missing errorr/rotation error
: LAMP ON
: LAMP OFF
: LAMP BLINK
1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restartafter power off.
Istherestarterroroccurredagain?
NO
YES
Isthe connectionof
compressorwireisnormal?
(PBA andCompressor)
NO
YES
Istherestarterroroccurredagain?
NO
YES
Isthecompressorbody and
interphaseresistanceinsulated?
NO
YES
Terminatetheservice
Connectthecomp wirenormally
Terminatetheservice
ExchangetheOutdoorPBA
Exchangethecompressor