10-2-15 When the Up/Down, Left/Right, Grill louver motor does not operate (Initial Diagnosis) (Not displayed)
1. Checklist :
1) Is the input power voltage normal?
2) Is the Up/Down louver motor properly connected with the connector? (CN61, CN62, CN63)
2. Troubleshooting procedure
Isthe lamp blinking?
Unplug the powercordand plug itafter
30secondslater.
NO
Check theasintheprocedure.
No power.
YES
Istheconnected louverwire?
NO
YES
Connectthe wirePBA to louvermotor
Isthe voltagechangeableatthepin#2~#5 of CN61,
CN62, CN63
(louverconnector)?
Doesoperationstart whenswing buttonof the
remotecontrol unitpushed?
YES
NO
NO
YES
Normal
Exchangethe PBA
Up/Downlouvermotoris faulty.