background image

ENGLISH

3

Safety precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and 

efficiently operate the extensive features and functions of your new appliance.
Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly 

from those described in this manual. If you have any questions, call your nearest contact center or find help and information 

online at www.samsung.com.

Important safety symbols and precautions:

WARNING

Hazards or unsafe practices that may result in 

severe personal injury or death.

CAUTION

Hazards or unsafe practices that may result in 

minor personal injury or property damage.

Follow directions.

Unplug the power plug from the 

wall socket.

Do NOT attempt.

Do NOT disassemble.

Make sure the machine is grounded to prevent electric shock.

FOR INSTALLATION

WARNING

Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this 

appliance only. In addition, do not use an extension cord.

  Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire.

  Do not use an electric transformer. It may result in electric shock or fire.

  If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

  Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury.

Install a switch and circuit breaker dedicated to the air conditioner.

  Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

  Failing to do so may result in electric shock or fire.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty 

location, in a location exposed to direct sunlight and water (rain drops).

 

Do not install this appliance in a location where 

gas may leak.

  This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

  If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

  Failure to do so may result in electric shock, fire, an explosion, or other problems with the product.

  Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and 

national codes.

FOR INSTALLATION

CAUTION

This appliance should be positioned in such a way that it is accessible to the power plug.

  Failing to do so may result in electric shock or fire due to electric leakage.

Install your appliance on a level and hard floor that can support its weight.

  Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the draining hose properly so that water is drained correctly.  

  Failing to do so may result in water overflowing and property damage.

When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.

  The water generated during the heating operation by the outdoor unit may overflow and result in property damage. 

 In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

USING PARTS

Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd   3

2011-3-19   10:07:26

Содержание AQ09UGFN

Страница 1: ...Boracay EUR_AQ09T U _IBIM_32447A_E indd 1 2011 3 19 10 07 24...

Страница 2: ...ries 26 Fixing the installation plate 27 Connecting the assembly cable 28 Installing and connecting the assembly pipe of the indoor unit 30 Purging the indoor unit 31 Cutting or extending the pipe 31...

Страница 3: ...tric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed Failing to do so may result in electric shock or fire Do not install this appliance near a h...

Страница 4: ...a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord Do not use a ventilating fan A spark may result in an explosion...

Страница 5: ...hock fire or problems with the product Do not drink the water from the air conditioner The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble t...

Страница 6: ...ction operates if an internal fault occurs in the air conditioner Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating De ice cycle The inte...

Страница 7: ...n Blade pin lever Air intake Air flow blade left and right Air filter underthepanel Air intake Room temperature sensor 09 12 18 24T 09 12 18 24U Air filter underthepanel Air flow blade up and down Bla...

Страница 8: ...ferent fan speeds such as Auto Low Medium High Set Set the timer mode Cancel Cancel the timer mode Air swing Activate Deactivate air flow blade movement automatically up and down Mode Set one of the 5...

Страница 9: ...tes on the rear side of the remote controller and pull up 2 Insert two AAA batteries Check and match the and signs accordingly Make sure you have inserted the batteries in correct position 3 Close the...

Страница 10: ...rature and the fan speed to feel cooler in hot season If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desire...

Страница 11: ...s the button to adjust the temperature Auto You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C...

Страница 12: ...button on the remote controller during Cool mode Turbo indicator appears on the remote controller display and the air conditioner operates inTurbo function for 30 minutes Move the blade pin lever left...

Страница 13: ...nd T U indicator on the indoor unit Set Off timer in mode over 5 hours You fell disturbed sleep if the is set too short or long because the default is set to 8 hour operation If the mode is set less t...

Страница 14: ...icator stops blinking and reserved time will be displayed for 3 seconds If you don t press Set button within 10 seconds after selecting the time the air conditioner will return to previous status Chec...

Страница 15: ...l set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode Press the SmartSaver button on the remote controller while the air conditioner is operatin...

Страница 16: ...operation Whentheairconditioneristurnedoff The Auto clean indicator on the indoor unit display appears and the Auto cleaning function runs Whentheairconditioneristurnedon After stopping the air condit...

Страница 17: ...acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the product or put any stickers on it They may damage the surface of the air conditioner Be car...

Страница 18: ...Air filter in a ventilated area Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Clean the Air filter every 2 weeks or when the filter clean r...

Страница 19: ...1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outsid...

Страница 20: ...r does not come out If the doors or windows are open it may cause bad cooling heating performance Close the doors and windows Check if the air conditioner has just been turned on after stopping coolin...

Страница 21: ...refrigerant flow movement changes It is normal Smoke is generated from the outdoor unit If may not be a fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during...

Страница 22: ...ly for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off a...

Страница 23: ...scaffolding or any other means of elevation won t be considered in warranty and charged to end user Power supply line fuse or circuit breaker Always make sure that the power supply is compliant with c...

Страница 24: ...picture below when installing the air conditioner Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Where sulfide gas exi...

Страница 25: ...d the air outlet is towards the wall 500 or more 300 or more The upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdo...

Страница 26: ...will not cause any effect Accessories The following accessories are supplied with the air conditioner The number of each accessory is indicated in parentheses Accessories in the indoor unit case Acce...

Страница 27: ...Finder TorqueWrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill LWrench MeasuringTape Tools for test operations Thermometer Resistance Meter Electroscope You can select the...

Страница 28: ...essary Do not connect two or more different cables to extend the length It may cause fire Make sure that a wall can withstand the weight of the product If you install the product in a place where it i...

Страница 29: ...ellow Ground wire Green Yellow Indoor unit Outdoor unit Ground wire Green Yellow Ground wire Green Yellow End of the wire must be circular After connecting the cables make sure terminal numbers on the...

Страница 30: ...ressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters The smalle...

Страница 31: ...e length of the pipe can be Extended up to see table page 24 Shorten up to see page 24 If you need a pipe longer than 5 meters You must extend the assembly cable You must add refrigerant to the pipes...

Страница 32: ...first with your hands and then with a torque wrench applying the following torque 7 For further details on how to connect to the outdoor unit and purge the air refer to page 34 36 Correct Uneven Thic...

Страница 33: ...and turning to the left 3 Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it t...

Страница 34: ...plug 3 Ensure that condensation draining is adequate Drain hole Drain plug To avoid drain plug from contacting the ground secure gap between the ground and the bottom surface of the outdoor unit In ar...

Страница 35: ...cap to the valve and tighten them at the torque of 183kgf cm with a torque wrench 8 Check for a gas leak paying particular attention to the 3 way valve s stem nuts and to the service port cap Refer t...

Страница 36: ...harge the refrigerant Important information regulation regarding the refrigerant used Charging the refrigerant under conditions of liquid by using a liquid pipe a Factory refrigerant charge of the pro...

Страница 37: ...alves discharge all the nitrogen from the system and create vacuum according to page 34 36 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the ref...

Страница 38: ...ce the outdoor unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exp...

Страница 39: ...f the air conditioner 6 Disconnect the pipes 3 Press the Airswing button and check the following The airflow blades work properly 4 Press the Power button to stop the operation 2 Press the Mode button...

Страница 40: ...insulation tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it wi...

Страница 41: ...ENGLISH 41 Memo Boracay EUR_AQ09T U _IBIM_32447A_E indd 41 2011 3 19 10 08 25...

Страница 42: ...amsung com KOSOVO 381 0113216899 LUXEMBURG 261 03 710 www samsung com MACEDONIA 023 207 777 MONTENEGRO 020 405 888 NETHERLANDS 0900 SAMSUNG 0900 7267864 0 10 Min www samsung com NORWAY 815 56 480 www...

Страница 43: ...DB98 32447A 1 Air Conditioner user installation manual imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www sams...

Отзывы: